YY-L200 LNG Loading Skid

Liquid design flow
60 m³/h
Vapor design flow
200 m³/h
Design temperature
-196 … +100 °C
Design pressure
0.88 MPa (liquid line)
YOYI YY-L200 · LNG Loading Skid

YY-L200 — LNG Loading Skid

Cryogenic loading skid for LNG: loading arm, flow meter, static alarm controller, pressure transmitter, loading control valve, emergency shut-off valve and batc

Media
LNG, -196 °C cryogenic
Lines
Loading / vapor return / N₂
Instruments
Cryogenic-rated YY series
Valves
Emergency shut-off included
  • ✓Cryogenic design materials and instruments selected specifically for -196 °C LNG service.
  • ✓Complete line package loading, vapor return, cold circulation, vent and nitrogen piping pre-integrated.
  • ✓Safe shutdown emergency shut-off valve interlocked with static & overfill protection.
Request a Quote Full Specifications

Technical Specifications

Operating temperature (liquid / vapor)-196 °C … 50 °C
Design temperature (liquid / vapor)-196 °C … 100 °C
Operating pressure0.55 MPa (liquid); 0.1 – 0.55 MPa (vapor)
Design pressure0.88 MPa (liquid); 0.78 MPa (vapor)
Design flow60 m³/h (liquid); 200 m³/h (vapor)
Process linesLoading line, vapor return line, cold circulation line, vent line, nitrogen line
Integrated equipmentLoading arm, cryogenic flow meter, static alarm controller, pressure transmitter, loading control valve, emergency shut-off valve, batch controller

Typical Applications

LNG terminalsLNG plantsCryogenic loadingPeak-shaving depots

Get a YY-L200 quotation

Every skid is custom-built. Share your media, gantry layout and throughput — we reply with a tailored configuration within one business day.

Request a Quote Talk to an Engineer
✉ annie@yoyimeter.com
☎ +86 18027268785

Downloads

Documents are sent by email on request — the latest revision is always provided.

Why Choose the YY-L200

  • ✓Factory integrated & tested pressure and loop tests completed before shipment.
  • ✓Custom-built every skid is tailored to your media, layout and throughput.
  • ✓Engineer support free layout review by YOYI application engineers.

Frequently Asked Questions

Why is an LNG skid more complex?

LNG is cryogenic with special properties; the process includes vapor return and cold circulation lines, and all instruments must be cryogenic-rated.

What pipeline functions are included?

Loading line, vapor return line, cold circulation line, vent line and nitrogen purge line as standard.

Can YOYI configure the full station?

Yes — the skid can be extended with LNG storage tank, cryogenic pump and dispenser interfaces per station scale.

Related Products

More YOYI Loading Skids

Ready to Specify the YY-L200?

Share your process data — a tailored proposal arrives within one business day.